제품 및 솔루션
Part No. Y64348
Y64348 / 2 pair 24AWG
Y64348
Extra Form Output
파트 넘버 Y64348 
제품 스팩 Y64348 
검색키워드 Y64348 / 2 pair 24AWGY64348Y64348 
총 상품금액 : 0

 

스크린샷 2025-08-18 100639.png

Y64348 Multi-Conductor - Low Capacitance Computer and Computer P.O.S. Cable

General Description

Low cap 24 AWG stranded (7x32) TC conductors, plenum, foam FEP insulation, twisted pairs, overall Beldfoil (100% coverage) + TC braid shield (90% coverage), 24 AWG stranded TC drain wire, Flamarrest® jacket.

Physical Characteristics (Overall)

Conductor

# Pairs

AWG

Stranding

Conductor Material

2

24

7x32

TC - Tinned Copper

Total Number of Conductors: 4

Insulation

Insulation Trade Name

Insulation Material

Wall Thickness (in.)

Teflon®

FFEP - Foam Fluorinated Ethylene Propylene

0.019

Outer Shield

Layer #

Outer Shield Trade Name

Type

Outer Shield Material

Coverage (%)

1

Beldfoil®

Tape

Aluminum Foil-Polyester Tape

100

2

 

Braid

TC - Tinned Copper

90

Outer Shield Drain Wire

AWG

Stranding

Drain Wire Conductor Material

22

7x32

TC - Tinned Copper

Outer Jacket

Outer Jacket Trade Name

Outer Jacket Material

Nom. Wall Thickness (in.)

Flamarrest®

LS PVC - Low Smoke Polyvinyl Chloride

0.015

Overall Cable

Overall Nominal Diameter: 0.273 in.

Pair Color Code Chart

Number

Color

1

White/Blue Stripe & Blue/White Stripe

2

White/Orange Stripe & Orange/White Stripe

Mechanical Characteristics (Overall)

Operating Temperature Range: -20°C To +75°C

Bulk Cable Weight: 38 lbs/1000 ft.

Max. Recommended Pulling Tension: 56.700 lbs.

Min. Bend Radius/Minor Axis: 2.750 in.

Applicable Specifications and Agency Compliance (Overall)

Program / Specification

Value

NEC/(UL) Specification

CMP

CEC/C(UL) Specification

CMP

EU Directive 2011/65/EU (ROHS II)

Yes

EU CE Mark

Yes

EU Directive 2000/53/EC (ELV)

Yes

EU Directive 2002/95/EC (RoHS)

Yes

EU Directive 2002/96/EC (WEEE)

Yes

EU Directive 2003/11/EC (BFR)

Yes

CA Prop 65 (CJ for Wire & Cable)

Yes

MII Order #39 (China RoHS)

Yes

Flame Test

Test

Result

UL Flame Test

NFPA 262

CSA Flame Test

FT6

Plenum/Non-Plenum

Plenum (Y/N): Yes

Electrical Characteristics (Overall)

Property

Value

Nom. Characteristic Impedance

120 Ω

Nom. Capacitance (Conductor to Conductor)

12 pF/ft

Nom. Capacitance (Cond. to Other Conductor & Shield)

22 pF/ft

Nominal Velocity of Propagation

76 %

Nom. Conductor DC Resistance @ 20°C

24 Ω/1000 ft

Nom. Outer Shield DC Resistance @ 20°C

2.4 Ω/1000 ft

Max. Operating Voltage - UL

300 V RMS

Max. Recommended Current

3.2 A per conductor @ 25°C

Print Legend

LEGEND: "BELDEN Y64348 CMP 2PR24 SHIELDED 75C (UL) E108998 C(UL) (1 METER, 4 DIGIT SEQUETIAL NUMBER) M"

Print legend notes:

METER MARKING TO RESET TO ZERO AT EVERY PUT-UP LENGTH. REQUIREMENT FOR ASCENDING (+0M to XXXM) PUT-UPS.

Revision

Revision Number: 1

Revision Date: 05-24-2021

logo
제품검색
Customer Center

031-795-5791~2

031-795-5793

9:30 - 16:30

문의하기