파트 넘버 | Y64348 | ||
---|---|---|---|
제품 스팩 | Y64348 | ||
검색키워드 | Y64348 / 2 pair 24AWGY64348Y64348 | ||
총 상품금액 : 0원 |
Y64348 Multi-Conductor - Low Capacitance Computer and Computer P.O.S. Cable
General Description
Low cap 24 AWG stranded (7x32) TC conductors, plenum, foam FEP insulation, twisted pairs, overall Beldfoil (100% coverage) + TC braid shield (90% coverage), 24 AWG stranded TC drain wire, Flamarrest® jacket.
Physical Characteristics (Overall)
Conductor
# Pairs |
AWG |
Stranding |
Conductor Material |
2 |
24 |
7x32 |
TC - Tinned Copper |
Total Number of Conductors: 4
Insulation
Insulation Trade Name |
Insulation Material |
Wall Thickness (in.) |
Teflon® |
FFEP - Foam Fluorinated Ethylene Propylene |
0.019 |
Outer Shield
Layer # |
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
1 |
Beldfoil® |
Tape |
Aluminum Foil-Polyester Tape |
100 |
2 |
|
Braid |
TC - Tinned Copper |
90 |
Outer Shield Drain Wire
AWG |
Stranding |
Drain Wire Conductor Material |
22 |
7x32 |
TC - Tinned Copper |
Outer Jacket
Outer Jacket Trade Name |
Outer Jacket Material |
Nom. Wall Thickness (in.) |
Flamarrest® |
LS PVC - Low Smoke Polyvinyl Chloride |
0.015 |
Overall Cable
Overall Nominal Diameter: 0.273 in.
Pair Color Code Chart
Number |
Color |
1 |
White/Blue Stripe & Blue/White Stripe |
2 |
White/Orange Stripe & Orange/White Stripe |
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +75°C
Bulk Cable Weight: 38 lbs/1000 ft.
Max. Recommended Pulling Tension: 56.700 lbs.
Min. Bend Radius/Minor Axis: 2.750 in.
Applicable Specifications and Agency Compliance (Overall)
Program / Specification |
Value |
NEC/(UL) Specification |
CMP |
CEC/C(UL) Specification |
CMP |
EU Directive 2011/65/EU (ROHS II) |
Yes |
EU CE Mark |
Yes |
EU Directive 2000/53/EC (ELV) |
Yes |
EU Directive 2002/95/EC (RoHS) |
Yes |
EU Directive 2002/96/EC (WEEE) |
Yes |
EU Directive 2003/11/EC (BFR) |
Yes |
CA Prop 65 (CJ for Wire & Cable) |
Yes |
MII Order #39 (China RoHS) |
Yes |
Flame Test
Test |
Result |
UL Flame Test |
NFPA 262 |
CSA Flame Test |
FT6 |
Plenum/Non-Plenum
Plenum (Y/N): Yes
Electrical Characteristics (Overall)
Property |
Value |
Nom. Characteristic Impedance |
120 Ω |
Nom. Capacitance (Conductor to Conductor) |
12 pF/ft |
Nom. Capacitance (Cond. to Other Conductor & Shield) |
22 pF/ft |
Nominal Velocity of Propagation |
76 % |
Nom. Conductor DC Resistance @ 20°C |
24 Ω/1000 ft |
Nom. Outer Shield DC Resistance @ 20°C |
2.4 Ω/1000 ft |
Max. Operating Voltage - UL |
300 V RMS |
Max. Recommended Current |
3.2 A per conductor @ 25°C |
Print Legend
LEGEND: "BELDEN Y64348 CMP 2PR24 SHIELDED 75C (UL) E108998 C(UL) (1 METER, 4 DIGIT SEQUETIAL NUMBER) M"
Print legend notes:
METER MARKING TO RESET TO ZERO AT EVERY PUT-UP LENGTH. REQUIREMENT FOR ASCENDING (+0M to XXXM) PUT-UPS.
Revision
Revision Number: 1
Revision Date: 05-24-2021