| 파트 넘버 | Y67897 | ||
|---|---|---|---|
| 제품 스팩 | Y67897 | ||
| 검색키워드 | Y67897 / 1 pair 22AWGY67897Y67897 | ||
| 총 상품금액 : 0원 | |||
Y67897 — Multi-Conductor - Low Capacitance Computer and Computer P.O.S. Cable
General Description
Low cap 22 AWG stranded (7x30) TC conductors, plenum, foam FEP insulation, twisted pair, overall Beldfoil (100% coverage) + TC braid shield (90% coverage), 22 AWG stranded TC drain wire, Flamarrest® jacket.
Physical Characteristics (Overall)
Conductor
| # Pairs | AWG | Stranding | Conductor Material | 
| 1 | 22 | 7x30 | TC - Tinned Copper | 
Total Number of Conductors: 4
Insulation
| Insulation Trade Name | Insulation Material | Wall Thickness (in.) | 
| Teflon® | FFEP - Foam Fluorinated Ethylene Propylene | 0.023 | 
Outer Shield
| Layer # | Outer Shield Trade Name | Type | Outer Shield Material | Coverage (%) | 
| 1 | Beldfoil® | Tape | Aluminum Foil-Polyester Tape | 100 | 
| 2 | Braid | TC - Tinned Copper | 90 | 
 | 
Outer Shield Drain Wire
| AWG | Stranding | Drain Wire Conductor Material | 
| 22 | 7x30 | TC - Tinned Copper | 
Outer Jacket
| Outer Jacket Trade Name | Outer Jacket Material | Nom. Wall Thickness (in.) | 
| Flamarrest® | LS PVC - Low Smoke Polyvinyl Chloride | 0.020 | 
Overall Cable
Overall Nominal Diameter: 0.214 in.
Pair Color Code Chart
| Number | Color | 
| 1 | White/Blue Stripe & Blue/White Stripe | 
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +75°C
Min. Bend Radius/Minor Axis: 2.1 in
Max. Recommended Pulling Tension: 29 lbs.
Applicable Specifications and Agency Compliance (Overall)
| Program / Specification | Value | 
| NEC/(UL) Specification | CMP | 
| CEC/C(UL) Specification | CMP | 
| EU Directive 2011/65/EU (ROHS II) | Yes | 
| EU CE Mark | Yes | 
| EU Directive 2000/53/EC (ELV) | Yes | 
| EU Directive 2002/95/EC (RoHS) | Yes | 
| EU Directive 2002/96/EC (WEEE) | Yes | 
| EU Directive 2003/11/EC (BFR) | Yes | 
| CA Prop 65 (CJ for Wire & Cable) | Yes | 
| MII Order #39 (China RoHS) | Yes | 
Flame Test
| Test | Result | 
| UL Flame Test | NFPA 262 | 
| CSA Flame Test | FT6 | 
Plenum/Non-Plenum
Plenum (Y/N): Yes
Electrical Characteristics (Overall)
| Property | Value | 
| Nom. Characteristic Impedance | 120 Ω | 
| Nom. Capacitance (Conductor to Conductor) | 13 pF/ft | 
| Nom. Capacitance (Cond. to Other Conductor & Shield) | 23.4 pF/ft | 
| Nominal Velocity of Propagation | 76 % | 
| Nom. Conductor DC Resistance @ 20°C | 24 Ω/1000 ft | 
| Nom. Outer Shield DC Resistance @ 20°C | 2.4 Ω/1000 ft | 
| Max. Operating Voltage - UL | 300 V RMS | 
Revision
Revision Number: 0
Revision Date: 06-23-2023
Print Legend
LEGEND: "BELDEN Y67897 CMP 1PR22 SHIELDED 75C (UL) E108998 C(UL) (1 METER, 4 DIGIT SEQUETIAL NUMBER)M"
Print legend notes:
METER MARKING TO RESET TO ZERO AT EVERY PUT-UP LENGTH. REQUIREMENT FOR ASCENDING ( +0M to XXXM) PUT-UPS.
 
						 
						